 Features
Regulated Converters

4:1 Wide Input Voltage Range 20 Watts Regulated Output Power 1.6kVDC Isolation Over Current and Over Voltage Protection Six-Sided Shield No Derating to 63C Standard 2" x 1" Package and Pinning Efficiency to 86%
POWERLINE
DC/DC-Converter
RP20S_DFW Series
20 Watt 2" x 1" Single & Dual Output
Selection Guide 24V and 48V Wide Input Types
Part Number Input Range VDC 9-36 9-36 9-36 9-36 18-75 18-75 18-75 18-75 9-36 9-36 9-36 18-75 18-75 18-75 Output Voltage VDC 3.3 5 12 15 3.3 5 12 15 5 12 15 5 12 15 Output Current mA 5500 4000 1670 1330 5500 4000 1670 1330 2000 833 667 2000 833 667 Input (4,5) Current mA 60/922 60/1016 75/1031 75/1014 30/461 30/508 40/515 40/507 85/1068 100/1028 100/1017 45/534 50/514 50/508 Efficiency(6) Capacitive(7) Load max. % F 84 86 85 86 84 86 85 86 82 85 86 82 85 86 18000 9600 1650 1050 18000 9600 1650 1050 4800 625 525 4800 825 525
RP20-243.3SFW RP20-2405SFW RP20-2412SFW RP20-2415SFW RP20-483.3SFW RP20-4805SFW RP20-4812SFW RP20-4815SFW RP20-2405DFW RP20-2412DFW RP20-2415DFW RP20-4805DFW RP20-4812DFW RP20-4815DFW
* no suffix for CTRL function with Positive Logic (1=ON, 0=OFF), this is standard * add /N for CTRL function with Negative Logic (0=ON, 1=OFF)
Derating Graph (Ambient Temperature)
RP20-4805SFW
125 100 75 Output Power (%) 50 25 0 -40 -25 -10 0
Natural Convection
18Vin
Nom Vin
50 60 70 80 90 100 110 Ambient Temperature Range (C) 63
Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact our technical customer service at info@recom-development.at
www.recom-international.com November-2006 259
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25C unless otherwise noted)
Input Voltage Range
RP20-S_DFW Series
24V nominal input 48V nominal input 9-36VDC 18-75VDC Pi Type 24V Input 48V Input 50VDC 100VDC 20mAp-p 20ms typ. DC-DC ON DC-DC OFF Nominal input Open or 3.0V < Vr < 12V Short or 0V < Vr < 1.2V 2.5mA 20W max. 1% 0% 0.2% Single Dual 0.5% 1% 5% 3.3V 5.0, 12, 15V 5, 12, 15V 60mVp-p 75mVp-p 100mVp-p 0.02%/C max. 250s complies with ETS300 132, part 4.4 5V/ms 150% typ Zener Diode Clamp 24V Input 48V Input DC-DC ON = 9VDC, DC-DC OFF = 8VDC DC-DC ON = 18VDC, DC-DC OFF = 16VDC Continuous, automatic recovery see Selection Guide" table In to Out and I/O to case 1600VDC min. 10 G min. 1500pF max. 400kHz typ. no derating with derating -40C to +63C -40C to +105C +105C -55C to +125C Natural convection with Heatsink 12C/Watt 10C/Watt Nickel plated copper Non-conductive black plastic continued on next page
Input Filter Input Surge Voltage (100 ms max.)
Input Reflected Ripple (nominal Vin and full load) Start Up Time (nominal Vin and constant resistor load) Remote ON/OFF (see Note 1) Remote OFF input current Output Power Output Voltage Accuracy (full Load and nominal Vin) Minimum Load Line Regulation (low line, high line at full load) Load Regulation (0% to 100% full load)
Cross Regulation Dual Output (asymmetrical load 25%/100% full load) Ripple and Noise (20MHz bandwith)
Temperature Coefficient Transient Response (25% load step change) Input Voltage Variation, dv/dt Over Load Protection (% of full load at nominal Vin) Overvoltage Protection (Single) Undervoltage Protection Short Circuit Protection Efficiency Isolation Voltage Isolation Resistance Isolation Capacitance Operating Frequency Operating Temperature Range Maximum Case Temperature Storage Temperature Range Thermal Impedance (see Note 8) Case Material Base Material
260
November-2006
www.recom-international.com
POWERLINE
DC/DC-Converter
Specifications, cont. (typical at nominal input and 25C unless otherwise noted)
Potting Material Weight Conducted Emissions (see Note 3) Radiated Emissions (see Note 3) ESD Radiated Immunity Fast Transient Surge Conducted Immunity Thermal Shock Vibration Relative Humidity MTBF (see Note 2) EN55022 EN55022 EN61000-4-2 EN61000-4-3 EN61000-4-4 EN61000-4-5 EN61000-4-6
RP20-S_DFW Series
Epoxy (UL94-V0) 27g Class A Class A Perf. Critera B Perf. Critera A Perf. Critera B Perf. Critera B Perf. Critera A MIL-STD-810D 10-55Hz, 2G, 30 Min. along X, Y and Z 5% to 95% RH Bellcore-TR-NWT-000332 2350 x 103 hours
Notes :
1. The RP20-S_DFW series requires a minimum of 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specification. 2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40C (Ground fixed and controlled environment). 3. Requires external filter to meet EN55022 Class A 4. Typical value at nominal input voltage and no load. 5. Maximum value at nominal input voltage and full load 6. Typical value at nominal input voltage and full load. 7. Test by minimum Vin and constant resistor load. 8. Optional Heatsink Part Number 7G-0020A 9. The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to negative input. Positive logic ON/OFF is standard, no suffix (Ex. RP20-2405SF) Negative logic ON/OFF is marked with suffix-N (Ex. RP20-2405SF/N).
Package Style and Pinning (mm)
50.80 25.40 10.20 dia. 1.0 15.20 20.30 5.6 2.50 5.10 3rd angle projection
Pin Connections
3 1 2 6
Bottom View
10.20
4
10.20
5
12.70
Pin # 1 2 3 4 5 6
Single +Vin -Vin +Vout Trim -Vout CTRL
Dual +Vin -Vin +Vout Com -Vout CTRL
Pin Pitch Tolerance 0.35 mm
External Output Trimming Single Output can be trimmed 10% by using external resistors See Application Notes for details
5
Trim Up RU
4
Trim Down RD
4
3
www.recom-international.com
November-2006
261


▲Up To Search▲   

 
Price & Availability of RP20-2412SFW

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X